ENGLISHHOMECONTACT USSITEMAP

제품정보
Kyongshin PRODUCT

Zymo Research

Bertin

Saphymo (Bertin)

Berthold

Serumwerk

Biocomp

Capitalbio

Arrayjet

PolyAn

Hudson Robotics

ABER instrument

Arthus Biosystems

BioChain

Povair

BIOREAGENT(Bertin)

Hudson Robotics
▪ HOME>제품정보>Hudson Robotics
Quadra4 Liquid Handling Workstation
The Quadra4 liquid handling workstation can be configured for a number of tasks. Including automated SPE – both positive and negative pressure, accurate sample transfers, precise standards additions, sample dilutions, and magnetic bead cleanup. When changing methods, no recalibration is required with Tomtec’s fixed 24, 96, or 384 tip pipetting heads, making Quadra4 simpler to operate than systems five-times its price. The Quadra4’s software, with optional 21CFR11 toolkit, enables use in both non-regulated and regulated environments. Optional automated plate stackers provide true walk-away high-throughput plate prep.
담당자 : 오상민

T) 02-576-6303
M) 010-4137-6303

이메일 : Victor@kyongshin.co.kr

제품소개

Description

With over 40 years of experience in automated liquid handling, the Tomtec Quadra4 Liquid Handling Workstation sets the standard for a cost effective liquid handling workstation for life science applications. The workstation is engineered around a reliable fixed-head air displacement syringe design which services a six-station shuttle. The six stations can support a wide range of accessories for automating sample preparation like solid phase extraction (SPE), magnetic bead cleanup, as well as dilutions and standards additions. With an optional plate-stacker, the Quadra4 can be used to queue up to 50 assays. With an easy to learn, user friendly WIN 10 64 bit graphical interface, the Quadra4 delivers speed, flexibility, and precision.

Each Quadra4 Liquid Handling Workstation is manufactured in our Connecticut and New Jersey facilities. Tomtec engineers work with your research team to understand your analytical sample requirements, and then recommend the best possible solutions at the best possible price. When the Quadra4 Liquid Handling Workstation is delivered to your laboratory, Tomtec engineers install and test your system and familiarize your team on how to get the most value from your Tomtec investment. With both air displacement pipetting, in conjunction with an optional indexing microplate stage, the Quadra4 Liquid Handling Workstation enables the support of complex pipette workloads found on workstations that cost five-times its price. In addition, the optional automated plate stacker’s provide true walk-away assay automation.

The Quadra4 provides:

  • Highly precise and consistent, accurate pipetting for 24, 96, 384 ANSI microplates.
  • Wide spectrum flow rate with the sensitivity and utility to handle a wide range of aqueous and organic solutions within the same workflow.
  • Process logs for assay validation and QC with full barcode support and LIMS integration.
  • Intuitive and flexible Graphical User Interface (GUI) for set-up and monitoring workflows

Specifications


Bioanalytical ApplicationsGeneral CapabilitiesPrecise Assay Automation
450ul tips with a cannula to access deep well platesFlexibility to support 96 well pipetting with either 450ul, 250ul, 50ul, or 20ul clear plastic tipsPrecision 96 well positive displacement pipetting at 60ul to 0.5ul @ ± 2.5%
Aqueous, to organic, to aqueous, without a tip changeAutomated serial dilution with either 8 or 12 tipsPrecision 384 well positive displacement pipetting at 60ul to 0.5ul@ ± 2.5%
Manual or automated vacuum box optionsPipette multiple reagents, within the same tip, using air gap separation to accelerate work-flowsAutomated 96 to 384 to 1536 reformatting
Stacker in-feed/out-feed for microplates and reservoirs provides walk away automationNon contact dispensing
Six station shuttle to support multiple microplates and reservoirsPipetting heads configured for 24 to 96 to 384 and/or 1536 well assays as well as specialized heads.
SPE Liquid/Liquid extraction, optional positive pressure SPECost effective Non sterilized and sterilized pipette available directly from Tomtec
Ultrasonic tip washing and magnetic bead toolsets available

Applications

Sample preparation for qualitative and quantitative LCMSMS

Sample preparation and transfer from 24 vials formats to microtiter plates formats

24 and 96 tip pipetting heads are ideal for blood/fecal samples in vials for prep for GC MS, then transfer to 96 well plates for LCMSMS

High Thoughput Screening for NME

Solid Phase Extraction

Sandwich ELISA

Genomics – Sample Preparation and PCR

Drug Testing (metabolites -NIDA-5)


Documents & Videos


Accessories




120686
Contaminated Tip Removal Assembly
320-30
96/384 Plate / Reservoir Nest, Standard Version 1-1/2” High (Used on Quadra 3/4 )
320-31
1536 Plate Nest (Used on Quadra 3/4)
320-34
96/384 Plate Reservoir Nest, Short Version 1” High (Used on Quadra 3/4)
320-40
384 PCR Plate Nest (Used on Quadra 3/4)
320-50
Tip Loading Fixture , 96 Well 450ul Head (Used on Quadra 3/4)
320-51
Tip Loading Fixture , 384 & 96 Well 55ul SV Head (Used on Quadra 3/4)
320-52
Tip Loading Fixture (Used on Pipetting Head Tip & Seal Power Wash System)
320-53
Tip Loading Fixture , 96 Well 20ul DSV Head (Used on Quadra 3/4)
330-10
BarCode Reader with Installation Kit. Used on Quadra 3 & Quadra 4 (4000 Series ONLY) 4100 Series – See 410-10
340-35
Teflon Coated Aluminum Reservoir
4000-730
Quadra 4 Command System Software (MS Windows)
890-710-12
Keyboard with Trackball, USB, Wireless (Used on Quadra 4)
OM4000
Quadra 4 Operator’s Manual
120322-02
Touch-Off Stage Assemblyy (Quadra 4 SPE/LTD – 4000 Series)
120322-03
Touch-Off Stage Assembly (Quadra 4SPE or LTD – 4100 Series)
196-503
SPE Vacuum Box w/ Control ModuleIncludes: 020484 & 330-59
410-10
BarCode Reader with Installation Kit. Used on Quadra 4 (4100 Series ONLY)
20484
SPE Vacuum Box Control Module ONLY
027107-01
PCR Tube Support Plate (Used on Quadra 3 / 4)
120329-01
Shaker Nest Auxiliary Power KitIncludes: Power Supply, Adapter, & Line Cord(Used with 320-75, 320-75J, 520-75, 520-75J Shaker Nest)NOTE: PURCHASE ORDER MUST INDICATE REQUIRED VOLTAGE & FREQUENCY
120955-02
Mirror Rack Nest Assembly (New Style), Quadra 4

주문정보

CAT.No 품명 규격 비고
Quadra4